LIDOCAINE, 2%, jelly, sterile, 30g, tube

STD DEXTLIDO2J3

Valid Article

Former Code(s): -X

The product is supplied (and stored) sterile, it must remain sterile until its use. Sterile = state of being free from all living microorganisms.
Classification of the medicines in groups and subgroups according to their therapeutic use. The classification used by MSF is based on the WHO Model List of Essential Medicines.
N01BB02
Anatomical Therapeutic Chemical Classification according to WHOCC
Thermosensitive codes are defined for storage and transportation temperature requirements of the products.

OC subscriptions: included in supply or field order tools (e.g. UniField)
SC subscriptions: included in supply or field tools
OC validations: approved for procurement and use by an OC for international or local orders specifying context and activity in Medical Standard Lists (MSL)

https://www.unicat.msf.org/web/image/product.template/571178/image_1920?unique=7fc8965

This combination does not exist.

Add article to list

   

Add Kit To Wishlist

   

LIDOCAINE 2% jelly, sterile

Therapeutic Action

Sterile, water-soluble, topical anaesthetic

Indications

Surface anaesthesia and lubrication during:

  • endotracheal intubation (oral and nasal)
  • Laryngeal Mask Airway (LMA) insertion

Instructions for use

2% lidocaine is equivalent to 20mg/ml lidocaine.

The 2% lidocaine jelly provides a rapid, deep anaesthesia of the mucous membranes, lasting approximately 20-30 minutes. Anaesthesia usually sets in within 5 minutes, depending on the surface area applied.

Lubrication for endotracheal intubation: apply 2 gr of lidocaine jelly to the external surface of the endotracheal tube just before use. Avoid introducing the jelly into the lumen of the tube.

Precautions for Use

Do not apply on the eyes.

Do not use to lubricate urinary catheter (use LUBRICANT, water based, sterile, unidose, 5g SMSULUBRW05S, or sterile water) or gastric tube (use drinking water).

Storage

  • Below 25ºC
  • Do not freeze.
  • Tightly close the tube after each use to prevent contamination.