KIT HF, TRANSCEIVER, mobile station, MN100 + IC700

STD KCOMKHFM100

Discontinued Article

OC subscriptions: included in supply or field order tools (e.g. UniField)
SC subscriptions: included in supply or field tools
OC validations: approved for procurement and use by an OC for international or local orders specifying context and activity in Medical Standard Lists (MSL)

This combination does not exist.

Add article to list

   

Add Kit To Wishlist

   

KIT HF, TRANSCEIVER, mobile station, MN100 + IC700

Definition

HF radio kit, wide band, programmable, with SelCall and scanning options, intended for a mobile configuration (does not allow data transmission).

INTENDED FOR PREWIRED VEHICLES.

(See for the Codan Envoy X1 as a base station the kit KCOMKHFBCE1).

Specifications

For the specifications, see the Logistic catalogue.

HF transceiver:

CLOSED ARTICLE: Codan Envoy X1

Antenna tuner for HF mobile radio:

CLOSED ARTICLE: Codan 3040

note: OCB/MSF Suply still delivers the kit with the Codan 9350 antenne.

Instructions for use

See the user manual included in the kit.

NEVER transmit (push the PTT button) without an antenna connected.

The Envoy X1 transceiver operates on 12 V battery. Caution, the use of a 24 V truck battery requires a 24 V/12 V adaptor.

The Envoy X1 micro-handset is not always interchangeable.

Any Envy X1 transceiver to be repaired should be sent back together with its microphone and its junction box.

For any problem related to signal quality, installation or antenna selection (bad SWR, skip zone, orientation), please contact your technical department.

The Codan Envoy X1 is proposed with software called NSP. But as the settings possibilities are either too basic or too sophisticated (too many changes authorized), MSF has developed its own software with 2 function levels and has integrated it into the radio:

First level (field)

  • channels can be created or erased
  • SelCall programming (if activated at the second level)
  • choice between USB and LSB mode
  • SelCall on/off
  • scan on/off
  • mute on/off
  • logs IN and OUT view
  • display brightness setting

Second level (CoTL/LogCo/RTL)

(Accessible only with a 6 digit password)

  • beep on/off
  • scan is ON when starting (possibility to change this mode)
  • mute is OFF when starting (possibility to change this mode)
  • possibility to set the SelCall to OFF (so that it cannot be on ON at the first level)
  • delay to restart
  • other functions
Some restricted information has been hidden. Sign in to see this information