DOSING PUMP (Dosatron D20) 20 m³/h, inj. 0.2 to 2%
                    NST
                    CWATDOSP2--
                
                Valid Article
                            Account code:
                            61010
                        
                        
                            HS Code:
                            841319
                        
                        
                            Last Updated on:
                            03/11/2025, 23:02:52
                        
                    
                Former
                    Code(s):
                     CWATZFR0659
                
            
            DOSING PUMP (Dosatron D20) 20 m³/h, inj. 0.2 to 2%
Definition
Mechanical dosing pump allowing continuous chlorination of water.
Specifications
DOSING PUMP
- Mechanical pump using the water pressure as a driving force (no need for electric power supply).
 - Water flow between 1 and 20 m3/h with a by-pass assembly.
 - Maximum nominal pressure: 10 bars.
 
Components
Part of the MODULE, DOSING PUMP, 1m³/h - 20 m³/h (Dosatron) KWATMDOS02-
Instructions for use
- Connect the dosing pump either to the public water supply system or to another water supply source (refer to the user guide supplied by the manufacturer)
 - Connect the dosing pump in the same direction as the water flow (see arrow on the Dosatron and on the regulator)
 - Always install the dosing pump on the discharge outlet of the pump
 - For the first use, start the pump and regulate the flow gradually
 - Adjust the positioning of the regulator's spring in order to adapt the opening of the valve according to the flow in your water pipe (refer to the adjustment graph)
 - Adjust the percentage of sucked up chlorine stock solution with the graduated dosing ring and test free residual chlorine at the outlet of the system
 - To clean the filter: decrease the flow of the pump and then put the filter on the filtering position
 - Clean the pump once a month by allowing it to suck up water without chlorine during 10 minutes
 - Protect the pump from the bad weather and sun
 