CHARGER-INVERTER (Victron Multiplus) 24/230V 120A 5kVA

NST PELECHIN22250

Valid Article

Former Code(s): PELEZFR0366


OC subscriptions: included in supply or field order tools (e.g. UniField)
SC subscriptions: included in supply or field tools
OC validations: approved for procurement and use by an OC for international or local orders specifying context and activity in Medical Standard Lists (MSL)

https://unicat.msf.org/web/image/product.template/547100/image_1920?unique=165c8fb

This combination does not exist.

Add article to list

   

Add Kit To Wishlist

   

CHARGER-INVERTER (Victron Multiplus) 24/230V 120A 5kVA

Form

Combined pure sine wave inverter and battery charger in a single enclosure. Designed for off-grid, backup, and hybrid power applications.

  • enclosure: aluminum, blue color (RAL 5012).
  • IP protection: IP20 (for dry indoor locations only).
  • terminals: 4 x M8 bolts for battery connections, M6 nuts for AC connections.
  • dimensions (H x W x D): 444 x 328 x 240 mm.
  • weight: 30 kg.

Per piece.

Fit

Electrical Specifications (Inverter):

  • input voltage: 19–33 VDC.
  • output: 230 VAC (± 2%), 50 Hz.
  • continuous power: 5000 VA / 4000 W (at 25°C).
  • peak power: 10,000 W.

Electrical Specifications (Charger):

  • AC input range: 187–265 VAC (45–65 Hz).
  • max charge current: 120 A (at 24V).
  • transfer switch: 100 A capacity.

Compatibility & Installation:

  • scalability: supports parallel operation (up to 6 units) and 3-phase network configurations.
  • battery compatibility: works with standard lead-acid and Lithium-ion battery banks.
  • communication: equipped with VE.Bus ports for integration with GX devices (e.g., Cerbo GX) and PC configuration.
  • environment: operating temperature from -40°C to +65°C (with fan-assisted cooling).

Function

Primary function:

  • provides uninterrupted 230V AC power to critical loads by switching (<20 ms) from grid/generator to battery power upon AC failure (UPS function).
  • charges 24V battery banks when external AC power is available.

Operation & Specific Features:

  • PowerAssist: prevents overload of a limited AC source by automatically supplementing it with power drawn from the batteries.
  • PowerControl: allows the user to set a maximum AC input current limit to avoid tripping external breakers.
  • dual AC outputs: main output provides UPS backup; the second output is only active when AC input is available, used to automatically disconnect non-critical loads during an outage.

Limitations:

  • heavy unit (30 kg); requires secure wall mounting.
  • advanced configuration (like setting up parallel operations or specific charging profiles) requires a specialized MK3-USB interface and Victron software.