MULTIMETER backlit (Fluke) small

NST PELEMEASMFLB

Valid Article



OC subscriptions: included in supply or field order tools (e.g. UniField)
SC subscriptions: included in supply or field tools
OC validations: approved for procurement and use by an OC for international or local orders specifying context and activity in Medical Standard Lists (MSL)

https://unicat.msf.org/web/image/product.template/558825/image_1920?unique=50ce526

This combination does not exist.

Add article to list

   

Add Kit To Wishlist

   

MULTIMETER backlit (Fluke) small

Form

Professional palm-sized digital multimeter designed for first-pass troubleshooting and basic electrical measurements, combining compact format with Fluke safety standards.

  • physical format: handheld, palm-sized unit with integrated protective housing
  • display: LCD, 6000 counts, backlit, update rate 3 readings/s
  • IP protection: IP40
  • power supply: 2 × AAA batteries (IEC LR03)
  • battery life: minimum 200 hours
  • maximum voltage to earth: 600 V
  • safety standard: IEC 61010-1, Pollution Degree 2; IEC 61010-2-033, CAT III 600 V / 10 A
  • electromagnetic environment: IEC 61326-1, portable
  • dimensions (H × W × L): 142 × 69 × 28 mm
  • weight: approx. 200 g

Includes:

  • 1 × Fluke 107 digital multimeter
  • 1 × TL75 Hard Point™ test lead set
  • 2 × AAA batteries (installed)
  • 1 × SmartStrap™ magnetic lanyard

Per piece.

Fit

Electrical measurement ranges:

  • voltage AC: up to 600 V (40 Hz – 500 Hz)
  • voltage DC: up to 600 V
  • current AC: up to 10 A (40 Hz – 200 Hz)
  • current DC: up to 10 A
  • resistance: up to 40 MΩ
  • capacitance: up to 1000 μF
  • frequency: 10 Hz to 100 kHz
  • duty cycle: 0.1 % to 99.9 %
  • diode test: yes
  • continuity: yes (audible)

Accuracy :

  • voltage DC: ±(0.5 % + 3 digits)
  • voltage AC: ±(1.0 % + 3 digits)
  • current AC/DC: ±(1.5 % + 3 digits)

Environmental conditions:

  • operating temperature: 0 °C to +40 °C
  • storage temperature: –30 °C to +60 °C

Function

Compact digital multimeter intended for everyday electrical troubleshooting where true-RMS accuracy is not required, providing reliable voltage, current, and component measurements in a highly portable format.

Primary functions:

  • measurement of AC and DC voltage for low-voltage electrical systems
  • measurement of AC and DC current up to 10 A
  • resistance and continuity testing for cable and circuit verification
  • capacitance, frequency, and duty-cycle measurements for basic electronic diagnostics
  • diode testing for semiconductor checks

Typical applications:

  • first-pass troubleshooting in electrical maintenance
  • basic measurements in commercial and light industrial installations
  • electrical and electronic diagnostics in confined or mobile work environments

Limitations:

  • not a true-RMS multimeter
  • no data logging or communication interface
  • IP40 limits use in wet or dusty environments