MULTIMETER backlit (Fluke) small
NST
PELEMEASMFLB
Valid Article
Account code:
61120
HS Code:
903190
Last Updated on:
04/02/2026, 22:03:26
MULTIMETER backlit (Fluke) small
Form
Professional palm-sized digital multimeter designed for first-pass troubleshooting and basic electrical measurements, combining compact format with Fluke safety standards.
- physical format: handheld, palm-sized unit with integrated protective housing
- display: LCD, 6000 counts, backlit, update rate 3 readings/s
- IP protection: IP40
- power supply: 2 × AAA batteries (IEC LR03)
- battery life: minimum 200 hours
- maximum voltage to earth: 600 V
- safety standard: IEC 61010-1, Pollution Degree 2; IEC 61010-2-033, CAT III 600 V / 10 A
- electromagnetic environment: IEC 61326-1, portable
- dimensions (H × W × L): 142 × 69 × 28 mm
- weight: approx. 200 g
Includes:
- 1 × Fluke 107 digital multimeter
- 1 × TL75 Hard Point™ test lead set
- 2 × AAA batteries (installed)
- 1 × SmartStrap™ magnetic lanyard
Per piece.
Fit
Electrical measurement ranges:
- voltage AC: up to 600 V (40 Hz – 500 Hz)
- voltage DC: up to 600 V
- current AC: up to 10 A (40 Hz – 200 Hz)
- current DC: up to 10 A
- resistance: up to 40 MΩ
- capacitance: up to 1000 μF
- frequency: 10 Hz to 100 kHz
- duty cycle: 0.1 % to 99.9 %
- diode test: yes
- continuity: yes (audible)
Accuracy :
- voltage DC: ±(0.5 % + 3 digits)
- voltage AC: ±(1.0 % + 3 digits)
- current AC/DC: ±(1.5 % + 3 digits)
Environmental conditions:
- operating temperature: 0 °C to +40 °C
- storage temperature: –30 °C to +60 °C
Function
Compact digital multimeter intended for everyday electrical troubleshooting where true-RMS accuracy is not required, providing reliable voltage, current, and component measurements in a highly portable format.
Primary functions:
- measurement of AC and DC voltage for low-voltage electrical systems
- measurement of AC and DC current up to 10 A
- resistance and continuity testing for cable and circuit verification
- capacitance, frequency, and duty-cycle measurements for basic electronic diagnostics
- diode testing for semiconductor checks
Typical applications:
- first-pass troubleshooting in electrical maintenance
- basic measurements in commercial and light industrial installations
- electrical and electronic diagnostics in confined or mobile work environments
Limitations:
- not a true-RMS multimeter
- no data logging or communication interface
- IP40 limits use in wet or dusty environments