REFRIGERATOR-FREEZER solar (Dulas VC150SDDSS) 102/42.9l

NSL PCOLSOLEUS1

Valid Article

OC subscriptions: included in supply or field order tools (e.g. UniField)
SC subscriptions: included in supply or field tools
OC validations: approved for procurement and use by an OC for international or local orders specifying context and activity in Medical Standard Lists (MSL)

This combination does not exist.

Add article to list

   

Add Kit To Wishlist

   

REFRIGERATOR-FREEZER solar (Dulas VC150SDDSS) 102/42.9l

Definition

Solar powered compressor chest fridge/freezer, used for storing temperature-sensitive products and freezing ice packs.

"SDD Solar Direct Drive" meaning no batteries or inverter is needed for this fridge to operate as intended by the manufacturer.

"SS" means Solar Socket. it is a socket with 2 connectorS, USB and cigaret lighter, able to charge small electric devices as phone, computer, etc, when fridge and freezer compressor do not need power. Priority is given to the 2 compressors.

Specifications

  • Power supply: 24 to 45 VDC
  • Minimum strating power refrigerator: 40W
  • Minimum strating power freezer: 40W
  • recommended solar panels: 600W, module, Vpmax >24 Vdc, Voc < 45 Vdc
  • Refrigerator gross storage capacity: 102 litres
  • Ice pack freezing capacity: 2.4 kg in 24 hrs
  • 0.6 litre ice pack storage capacity: 20
  • Holdover time without power at 43 ºC: 77.9 hrs
  • Automatic thermostat
  • Refrigerant gas: R600a
  • Compressor type: Danfoss Secop BD35K
  • Lockable lid
  • Dimensions L x W x H: 99.2 x 128.3 x 73.5 cm
  • Weight: 170 kg
Some restricted information has been hidden. Sign in to see this information

Instructions for use

It is important to read the manufacturer installation manual and follow the instructions precisely before starting the unit.

For all information concerning storage and handling of the products to be stored, refer to the "preliminary remarks" at the start of this family.

Affix a temperature recording form (ALSTTEMP41E) to each freezer.

Caution
A compressor freezer should be left to rest for 24 hours after transportation before being switched on, in order to allow the lubricating oil to drain back into the compressor.

Never tilt a compressor freezer by more than 45°.