REACTOR UV (Germi CP 75 EP) 3x75W, 4PSE electro photo

NST CWATTREAUG-

Valid Article

OC subscriptions: included in supply or field order tools (e.g. UniField)
SC subscriptions: included in supply or field tools
OC validations: approved for procurement and use by an OC for international or local orders specifying context and activity in Medical Standard Lists (MSL)

This combination does not exist.

See Related

Add article to list

   

Add Kit To Wishlist

   

REACTOR UV (Germi CP 75 EP) 3x75W, 4PSE electro photo

Form

UVC reactor consisting of a stainless steel treatment chamber and 3​ UVC lamps of 75 Watts.

Technical characteristics:

  • Flow of water treated: 30 to 45 m3 / h, with an average flow of 23 m3 / h.
  • Ultraviolet treatment chamber in 316L stainless steel - IP65.
  • Reactor diameter UV CP 75 EP: 168 mm outside.
  • UV Germi length of the reactor: 989 mm.
  • Input and output U-2 "1/2 male thread.
  • Maximum pressure: 8 bar.
  • UV GERMI reactor is equipped with a photosensor for warning of insufficient irradiance.
  • UV reactor equipped with 3 UVC lamps of 75 Watts.

Characteristic of the electrical box:

  • Pack Dimensions: 230 x 280 x 110 mm.
  • Food and output: 230 V / 50 Hz, 225 Watts.
  • Equipped with:
  • 3 LED lamp operating 75W UVC.
  • 1 buzzer default UVC lamps.
  • 1 operating hours counter UVC lamps
  • 1 switch.

Definition of UVC lamps:

  • 3 UV lamps 75 W is electric power of 225 Watts.
  • Germicidal power: 75 Watts UV-C
  • Life lamp 9000 hours or 1 year, within the limit of maximum 5 starts per 24 hours.
Image

Fit

U-shaped inlet and outlet 2 "1/2 male to screw.

Power and power: 230 V / 50 Hz, 225 Watts.

Function

To bacteriologically treat water by the germicidal action of ultraviolet rays.

Allows to treat a water flow of 16.2 m3 / h at 31 m3 / h for transmittance values ​​between 92% and 98%, and a UV dose of 25 mJ / cm2 at 40 mJ / cm2. Average flow 23 m3 / h.

Setting up:

Installs horizontally, on the water supply pipe and must be placed on brackets fixed to the wall or placed on the ground on the support brackets.

Leave room either 1 m on the side of the lamps in order to replace the lamps, or provide for the easy dismantling of the device (by-pass), in order to be able to change the 75W UV lamps or the quartz sleeves.

It is recommended to instal a valve before and a valve after the generator.

Turbidity decreases the quality of water irradiation by ultraviolet rays.

The reactor must be isolated from "water hammer". It must be protected from frost, excessive heat and humidity (indoor installation).

As a precaution and to ensure longevity, the UV generator must be connected to a dedicated electrical line.

Maintenance:

The lifetime of 75W UV lamps is 9000 hours of operation. The generator's electronic box provides information on the remaining time of use.

Clean the quartz sleeves at least each time you change the TUV 75W lamps and check the gaskets.