TESTER electrical safety (Martindale HPAT400/2)
NST
PELEMEASJM4
Valid Article
HS Code:
903190
Last Updated on:
04/02/2026, 22:03:08
TESTER electrical safety (Martindale HPAT400/2)
Form
Battery-powered portable appliance tester designed for simple and rapid pass/fail testing of Class I, Class II appliances and power leads using automatic test sequences.
- physical format: Handheld portable unit with integrated protective housing
- fisplay: Monochrome LCD with backlight and PASS / FAIL indication
- IP protection: IP20
- power supply: 6 × AA alkaline batteries
- battery life: Minimum 600 complete tests
- overload protection: 300 V AC / DC
- safety standard: BS EN 61010-1
- operating temperature: −10 °C to +40 °C (non-condensing)
- dimensions (L × W × H): 210 × 90 × 54 mm
- weight: Approx. 700 g (including batteries and leads)
Includes:
- 1 × HPAT400 HandyPAT tester
- 1 × TL67 earth bond probe with crocodile clip
- 1 × EX322 IEC adaptor lead
- 6 × AA alkaline batteries
- 1 × TC57 zip carry case
- 1 × instruction manual
Per piece.
Fit
Earth continuity test:
- test voltage: 4 V DC (open circuit)
- test current: 200 mA DC (short circuit)
- accuracy: ± 0.03 Ω
- pass limits:
- lead ≤ 0.20 Ω = PASS
- Class I ≤ 0.20 Ω = PASS
Insulation resistance test:
- fixed test voltage: >500 V DC at 1 mA
- open circuit voltage: < 625 V DC
- test current: 1.5 mA (short circuit)
- accuracy: ± 0.1 MΩ
- pass limits:
- lead ≥ 1.0 MΩ
- Class I ≥ 1.0 MΩ
- Class II ≥ 2.0 MΩ
Fuse check:
- test voltage: 4 V DC (open circuit)
- test current: 200 mA DC (short circuit)
- pass level: > 2 mA
Test sequences (automatic):
- IEC power lead test
- Class I appliance test
- Class II appliance test
- extension lead test (using IEC adaptor lead)
Measurement principle:
- fixed test settings only
- automatic test sequence with PASS / FAIL result
- no numeric measurement display
Function
Portable appliance tester intended for basic electrical safety verification of portable appliances and power leads by trained personnel, using predefined automatic test sequences with clear PASS / FAIL indication.
Primary functions:
- verification of earth continuity on Class I appliances and leads
- verification of insulation resistance on Class I and Class II appliances
- fuse continuity check in appliance and lead plugs
- polarity and wiring verification on IEC leads
- automatic execution of complete test sequences without parameter adjustment
Intended use cases:
- routine PAT testing in offices, workshops, warehouses, and field installations
- rapid screening of appliances where numeric result recording is not required
- environments requiring simple, robust, battery-powered PAT testing
Limitations:
- no adjustable test limits
- no selectable insulation voltage
- no memory or data logging
- no Bluetooth or USB communication
- not suitable for surge-protected equipment requiring 250 V insulation testing