VACCINE CARRIER (Blowkings) 2.4l + 4 icepacks 0.6l, set

NST PCOLBOXCL4-

Valid Article



OC subscriptions: included in supply or field order tools (e.g. UniField)
SC subscriptions: included in supply or field tools
OC validations: approved for procurement and use by an OC for international or local orders specifying context and activity in Medical Standard Lists (MSL)

https://www.unicat.msf.org/web/image/product.template/589252/image_1920?unique=cdace65

This combination does not exist.

Add article to list

   

Add Kit To Wishlist

   

VACCINE CARRIER (Blowkings) 2.4l + 4 icepacks 0.6l, set

Form

Specifications:

  • Main vaccine storage capacity: 2.40 litre
  • External dimensions (LxHxW): 325 x 327 x 325 mm
  • Vaccine storage dimensions (LxHxW): 114 x 182 x 115 mm
  • Cold life at +43°C: 39:26 hrs:mn
  • Warm life at - 20°C: 23:05 hrs:mn
  • Weight empty: 3.5 kg
  • Minimum Rated Ambient Temp: 15.00°C
  • Icepacks: it comes with 4 x 0,6 L icepacks.

Standards and norms:

  • Applicable PQS specification: E004/VC02.1 Applicable PQS VP(s): E004/VC02-VP.1

Materials:

  • Insulation materials Polyurethane
  • Insulation thickness (mm) 40 MM
  • External materials Polyethylene
  • Internal lining materials Polyethylene

Fit

It can be used with 0,4 and 0,6 L icepacks.

Function

Ensures safe transport of vaccines at controlled temperatures, maintaining cold chain integrity.

This is a freeze-preventive vaccine carrier, which has some key similarities and differences compared to regular vaccine carriers:

  • The ice packs used in freeze-preventive vaccine carriers should not be conditioned. They should be used directly from the freezer without prior conditioning. They perform better when taken directly from the freezer without prior conditioning.
  • The internal temperature of the vaccine carrier will never drop below 2 °C, even when using non-conditioned ice packs.
  • The time required for the interior of the vaccine carrier to cool down and reach a temperature below 8 °C is longer than with a regular vaccine carrier. Therefore, the internal temperature must be monitored and reach < 8 °C before placing any medical items inside.
  • This freeze-preventive vaccine carrier can be used with any medical product in the same way as a regular vaccine carrier.
  • Since ice packs do not need to be conditioned but take longer to cool down and reach 8 °C inside, it is recommended to prepare the freeze-preventive vaccine carrier the night before use