MOVEMENT DETECTOR (Plexo) 500VA 3-wires, w/o support, IP55
NST
PELECOMMQM155
Valid Article
Last Updated on:
29/03/2026, 22:02:49
MOVEMENT DETECTOR (Plexo) 500VA 3-wires, w/o support, IP55
Form
Weatherproof automatic switch ( Mouvement detector ), designed to replace traditional mechanical switches in residential, professional plant rooms, and outdoor environments.
- materials: opalescent white plastic lens, PC mechanism casing, and ABS cover plate.
- protection: IP20 (mechanism only) / IP41 (when mounted with support frame and plate).
- impact resistance: IK04.
- thermo-sensitivity: operating temperature from +5°C to +45°C.
- fire resistance: self-extinguishing housing (850°C/30s for live parts).
- dimensions (H x W x D): 70.5 x 70.5 x 45.6 mm.
Per piece.
Fit
Interfaces & Compatibility:
- wiring system: 3-wire connection (strictly requires a neutral connection).
- supply voltage: 110–240 V AC, 50/60 Hz.
- mounting: compatible with standard Plexo range support frames and plates.
- master/slave linking: supports parallel wiring of up to 10 units (100 m maximum cable length).
- auxiliary control: can be combined with supplementary pushbuttons.
Installation & Terminals:
- terminals: screw-type terminals (designed for a 4 mm flat screwdriver).
- terminal capacity: 2 x 1.5 mm² or 1 x 2.5 mm² conductors.
- stripping length: 8 mm.
Function
Primary function:
- provides automatic ON/OFF control of a light source by utilizing passive infrared (PIR) technology to detect physical movement within its surveillance zone.
Electrical Ratings & Performance:
- load compatibility: designed to drive LEDs, incandescent, halogen, and fluorescent lighting systems.
- load capacity (at 240 V AC): up to 500 VA for LEDs, 2000 W for incandescent/halogen lamps, and 1000 VA for fluorescent loads.
- load capacity (at 110 V AC): up to 250 VA for LEDs, 1000 W for incandescent/halogen lamps, and 500 VA for fluorescent loads.
- maximum current: 8.5 A.
- standby power consumption: < 0.015 W.
- detection angle: 170°.
- detection range: up to 8 meters.
- time delay adjustment: user-configurable from 5 seconds to 30 minutes.
- light level threshold: adjustable from 5 to 1275 lux (includes MAX and OFF positions).
Environment & Storage:
- storing conditions: 0°C to +45°C.
- environment: suitable for damp and outdoor locations (e.g., garages, cellars, car parks, terraces, and gardens).
Limitations:
- strictly requires a neutral wire; not interchangeable with legacy 2-wire installations (like the 0 695 20LA model).
- transformer losses must be explicitly taken into account when calculating the total load power.
- in master/slave configurations, the time delay setting on all connected automatic switches must be approximately equal (± 10%).
- lens must be kept clean; dust or dirt accumulation will severely reduce detection reliability.