MOTOR PUMP diesel (Atlanta 8LD740.2L) 56m3/h. at 65m

STD CWATPUMEDA8

Discontinued Article

Former Code(s): CWATPUMDP56 CWATPUMEP56
OC subscriptions: included in supply or field order tools (e.g. UniField)
SC subscriptions: included in supply or field tools
OC validations: approved for procurement and use by an OC for international or local orders specifying context and activity in Medical Standard Lists (MSL)

This combination does not exist.

Add article to list

   

Add Kit To Wishlist

   

MOTOR PUMP diesel (Atlanta 8LD740.2L) 56m3/h. at 65m

Form

This article has been discontinued.

Surface centrifugal pump, delivering maximum 65 metre head and 56m³/h maximum flow. Powered by a diesel Atlanta 8LD740.2L engine. All mounted in a metallic frame.

Pump specifications:

  • Max 56 m³/h
  • Max 65 m.
  • Suction and discharge diameter: 3"

Fit

Connects with 3" pipes.

Main component of:

KIT MOTOR PUMP DIESEL, Atlanta, high head 56 m3 at 65 m (KWATKPUDP56)

Function

  • Used to pump water from a surface reservoir or source.
  • Needs proper periodic maintenance.
  • Is rated to pump raw water of a relatively low turbidity.
  • Not suitable for sewage, septic tanks and wastewater in general. Pumps used for non-potable water should not be used for delivering treated potable water.
  • Recommended to order the kit with all accessories instead of the separate pump.

For further information: "Public Health Engineering in Precarious Situations", MSF, 2nd edition, 2010:

  • T.B. 2.25 Centrifugal pumps
  • T.B. 2.28 Motor pump kit installation