NEBULIZER + COMPRESSOR (PariMobile S)
Stopped and made NST in 2019: replaced by the PARI Boy Pro EEMDNECE6-- (see “replaced by” at bottom of the page)
Definition
Electrical device allowing to nebulize a bronchodilator so that it can be administered as an inhalant. It delivers the medicine to the patient in a liquid phase going through the respiratory tract by creating small particles in the air to treat respiratory diseases.
The use of a nebuliser enables to deliver a medicine at higher dose compared to standard inhalers.
Specifications
Some restricted information has been hidden. Sign in
to see this information
Quality standards
EN 13544-2, 2002, +A1 2009 Respiratory therapy equipment. Tubing and connectors
Components
- 1 compressor Mobile S 47G1000 with 1 nebulizer LC Sprint, including:
- 1 tubing
- 1 mouthpiece
- 1 charger
- 1 battery
- 1 filter
- 1 adapter 12 V
- 1 transport bag
- 4 reusables Nebulizer LC SPRINT 23G1001 with 4 single use tubings (EEMDNECA206) and 4 reusable mouthpieces
- 5 reusable adult masks ref. 41G0740
- 5 reusable child mask ref. 41G0741
- 5 filters ref. 41E4852
Technical specifications
- Portable nebulizer operated by an electrical compressor
- Works on mains or battery (< 10 Wh). rechargeable on cigar-lighter
- The flow, nebulization rate and inhalation time are preadjusted.
- Average functionning flow : 4.5 L/min
- Functionning pressure : 1.2 bar
- Filling volume is between 2 and 8 mL
- MMDA : 3.8 µ - 65 % < 5 µ
- Nebulizers, masks and mouthpieces are autoclavable at 121 °C or 134 °C according the duration of the step. Please conform to the recommendations of the sterilisation referent.
- The tubing between nebulizer and compressor is single use and must be replaced between each patient (EEMDNECA206)
- CAUTION : if you nebulize medicines to newborn with T1 and T2 masks (not included in the basic composition), please ensure that the curved piece is present between the nebuliseur and the mask to enable the newborn to breath out.
Dimensions
8.9 x 4.5 x 14.7 cm
Packaging & Labelling
Unit packaging
Transport Dangerous Goods
- UN3481 Lithium ion batteries contained in equipment
- Class: 9
- Packing Instructions: 967 Section II
- The label must include the UN code of the battery + an emergency number to contact in case of an incident
- Limit per package:
- Pax A/C (Passengers & Cargo Aircraft) = 5 kg
- CAO (Cargo Aircraft Only) = 5 kg
Instructions for use
Some restricted information has been hidden. Sign in
to see this information
Precautions for Use
For the treatment of baby, child and dependent people, nebulizing must be realised under the continuous surveillance of a medical staff.
Maintenance
- Air filter removal
- Usual cleaning
- Sterilisation of the masks, mouthpieces, nebulisers by the autoclave
Some restricted information has been hidden. Sign in