MODULE, LIGHTING, for tent
Valid Article
MODULE, LIGHTING, for tent
Definition
Lighting system intended for standard tents of 27.5 m² and 42 m². Ready to be installed.
Indications
The lighting level enables staff to work or read without disturbing patients who are sleeping.
Sockets are removable to allow changes in the configuration (they leave only 2 small perforations in the wiring, easily insulated).
Screw type bulbs, E27 base, LED, 470 lumen, 2200K (easy to find locally). The kit was developed intentionally with yellow light bulbs, as yellow light attracts less bugs and flies than white light.
Delivered with 32 spare bulbs.
Electric board:
- 230 V
- 3 outlets 16 A, 2 pins + 1 ground.
- hybrid plug and socket NF or Schuko
- inlet cable 2.5 mm², 5 metre
- watertight, shockproof, unbreakable casing for outdoor use
- eyelet for wall fixation
- RCBO 30 mA
Instructions for use
Mount the garlands along the tent ridge pole, with the self locking ties.
Garlands can be connected to each other (from tent to tent) with the extension cords.
The plugs are not watertight and should not be exposed to rain or water.
The electric board is meant for a 3-4 kVA generator. It can also be used as protection device in case of mains power supply.