KIT, WATER TREATMENT UNIT, 5-8 m³/h

https://unicat.msf.org/cat/product/15729
STD KWATKTRE05-

Valid Article

Former Code(s): -X
The order of this product needs to be justified and is only acceptable under certain conditions.
OC subscriptions: included in supply or field order tools (e.g. UniField)
SC subscriptions: included in supply or field tools
OC validations: approved for procurement and use by an OC for international or local orders specifying context and activity in Medical Standard Lists (MSL)

This combination does not exist.

See Related

Add article to list

   

Add Kit To Wishlist

   

KIT, WATER TREATMENT UNIT, 5-8 m³/h

Definition

Kit allowing to produce 5 to 8 m3/h of drinking water from poor quality surface water (up to 300 NTU) through coagulation / flocculation, direct filtration and chlorination.

Indications

Technical specifications:

  • 50 m3/day (12h/day)
  • Consists of the modules 1 to 4 + 6, but can easily be upgraded to 10 m3/h by adding 2 x the module 5

The kit is composed of 5 modules containing all the accessories and consumables required to install and operate the water treatment unit:

  • Module 1: COAGULATION

Filter + suction side doser and analysis equipment

  • Module 2: FLOCCULATION

Filter + hose, tools and spare parts

  • Module 3: CONTROL PANEL

Filter + control panel

Filter + pressure-flow-turbidimeter and chlorinator

  • Module 5: ADDITIONAL FLOCCULATION (2x)

Filter + additional hoses

  • Module 6: CONSUMABLES, RTR (regulated transport)

Chlorine tablets, coagulant (FeCl3) and iron test

Remark

This kit also comes in a "10 m3/h" version (KWATKTRE10-), available on request or order 2 x the module 5 (KWATMTRE15-) to upgrade it to 10 m3/h.

Please contact the Watsan unit in MSF-OCB for further information.

Instructions for use

Kit supplied with detailed operator manual (a technician should be able to do the installation and to run the water treatment unit).

Train the staff in proper operation and maintenance of the unit.

Remarks

The quality of the filtered water is a lot higher in comparison with the water treated by assisted sedimentation (less coagulant residuals, less micro-biological content). The water treatment unit is therefore highly suitable for supplying drinking water to health structures (hospitals, cholera units or feeding centres…), refugee camps and communities.

The water treatment unit was originally designed to be used during the first phase of an emergency (3 to 6 months), but it has proven its reliability by functioning over several years in many missions. However, considering the operating costs and the need of supervision of the water treatment unit, other options (e.g. groundwater) should be considered for long term water supply.

Caution

The kit does not include the pump, water tank, distribution hoses or taps. These should be ordered separately according to your needs.

The unit is designed to work with the 30 m3/h petrol motor pump, (KWATKPUP30-), but functions just as well with the 60 m3/h diesel motor pump (KWATKPUP060).

For more detailed information and instructions see also the Manual WTU (integrated in kit).

Some restricted information has been hidden. Sign in to see this information
Some restricted information has been hidden. Sign in to see this information