UPS double conv. (Delta Amplon RT-6K) 6kVA, 230VAC + battery

STD PELEUPSD06D

Valid Article

Former Code(s): PELEUPSD6-- B PELEZNL0223
Hazardous materials and products (identified by their 4-digit transport UN-number) must be transported under certain conditions as specified in the MSDS sheet (Material Safety Data Sheet).
OC subscriptions: included in supply or field order tools (e.g. UniField)
SC subscriptions: included in supply or field tools
OC validations: approved for procurement and use by an OC for international or local orders specifying context and activity in Medical Standard Lists (MSL)

This combination does not exist.

See Related

Add article to list

   

Add Kit To Wishlist

   

ON-LINE UPS (Delta Amplon RT-6K)

Definition

A double conversion uninterruptible power supply (UPS) guarantees a perfect AC supply and is especially suitable for vulnerable and/or expensive equipment such as medical and laboratory equipment.

There is no connection between the incoming power and the outgoing power; all possible electrical problems such as voltage spikes are eliminated.

To function it needs a battery pack, which has to be ordered separately.

Specifications

  • Input voltage range 100 - 300 V (note that between 100 V and 180 V input voltage, the output power is reduced by 50 - 100%; full power is available only at 180V AC and above). At higher (>300 V) or lower (<100 V) voltages the UPS switches to battery power
  • Input and output frequency 50 or 60 Hz
  • Power factor >0.99
  • Efficiency (full load) >92%
  • Battery cabinet: 16 x 9 Ah, 12 V batteries in one cabinet; energy content approximately 1 kWh.
Some restricted information has been hidden. Sign in to see this information

Transport Dangerous Goods

UN2800: special provisions in air (A67) and sea (238) that allow us to send the product as not subject to regulation.

You need to prove that batteries have past vibration test, pressure differential test and leakage test. These tests should be mentioned on the MSDS or on additional documentation.

Instructions for use

This UPS is primarily intended to protect the equipment connected to it. It also provides back-up power but it cannot be configured to allow a long back-up time. An additional battery pack can be added to give a longer back-up time but the charger is integral and cannot be changed.

The high output power makes it suitable for almost any laboratory or medical facility. The UPS is delivered without a power cord and needs to be wired with an appropriate cable. Only connect 30 mA residual current devices (RCD) on the output of the UPS. RCD installed on input may be experience nuisance tripping.

For more details and advice: contact your logistics department.

MSF requirements

The chosen model enables input voltages of 100 – 300 V to be converted to 230 V; the input is compatible with 50 or 60 Hz; the output can be programmed to the local frequency if need be.