GLOVE, EXAMINATION, nitrile, s.u., non sterile, M
STD
SMSUGLEN1M-
Valid Article
Account code:
60210
HS Code:
401512
Last Updated on:
20/12/2024, 22:01:52
Former
Code(s):
-X
Single use
A single-use device, also referred to as a disposable device, is intended for use on one patient during a single procedure. It is not intended to be reprocessed (i.e., cleaned and disinfected or sterilized).
T01020204 - Nitrile examination / treatment gloves
European Medical Device Nomenclature (EMDN) is the nomenclature of use by manufacturers when registering their medical devices in the EUDAMED database. EMDN is characterised by its alphanumeric structure that is established in a seven-level hierarchical tree.
In Europe, medical material that fulfills the definition of a medical device according to the MDR (Medical Device Regulation) is classified into 4 classes
Thermosensitive codes are defined for storage and transportation temperature requirements of the products.
EXAMINATION GLOVE, nitrile
Definition
Disposable non sterile glove used to protect both patient and staff from infections transmitted through contact with the hands.
Synonym
protective glove, procedure glove
Specifications
Quality Standards Comment
Technical specifications
- 100% nitrile, non powdered
- Ambidextrous shape (fits either hand)
- Thickness at fingers: max 0.1 mm
- Cuff: straight or rolled edge
- Different colour than latex examination gloves is preferred
- Non sterile, for single use
- Dimensions: 3 sizes: small (S), medium (M) and large (L)
Size | Minimum length | Palm width |
small | 240 mm | 80 ± 10 mm |
medium | 240 mm | 95 ± 10 mm |
large | 240 mm | 110 ± 10 mm |
Packaging & Labelling
Cardboard distribution box of 100, 150 or 200 gloves.
The labelling must mention: "non powdered glove".
Instructions for use
Some restricted information has been hidden. Sign in
to see this information
Precautions for Use
- STRICTLY SINGLE USE
- Wash hands before and after use of gloves
- To be worn only on dry hands
- Discard defective or deteriorated gloves.
- Remove and replace gloves which are damaged while in use
- Carefully follow undressing procedure when gloves are removed
- Once removed, the gloves should be disposed of according to waste management rules
- For laboratory procedures in BSL2 and BSL3, the nitrile gloves with extended cuffs are recommended (see SPPE family).
Storage
- Store below 30°C, Protect from sunlight ‐ Protect from humidity
- In the original packaging
MSF requirements
Non powdered glove, allowing the use of hydroalcoholic solution as hand cleanser
Some restricted information has been hidden. Sign in
to see this information