GENERATOR (Yanmar eG140i-5F) 10kVA 230V 50Hz, diesel
NST
PELEGENEA1025
Valid Article
Account code:
61120
Last Updated on:
11/12/2024, 21:03:43
Former
Code(s):
PELEZFR0480
Hazardous materials and products (identified by their 4-digit transport UN-number) must be transported under certain conditions as specified in the MSDS sheet (Material Safety Data Sheet).
GENERATOR (Yanmar eG140i-5F) 10kVA 230V 50Hz, diesel
Definition
Diesel generator, INTENDED FOR EMERGENCIES.
Specifications
- type : Yanmar Eg140i
- stand-by power: 11 kVA
- prime power: 10.2 kVA
- rated voltage: 240 V
- Number of phases: single phase, 2 wires
- Rated frequency: 50 Hz
- Rated current: 44.4 A
- RPM : variable: 2300 – 3400
- Weight : 280 kg (generator only)
- MTBF : 5000 hour
- Service interval: 250 hour
- Electric protections:
- Main plug : 50 A magneto-thermic circuit-breaker
- Auxiliary plug: 16 A magnetothermic circuit-breaker + 30 mA Residual Current Device
- Output power is stabilized by inverters which ensure the quality of the signal, eliminating the need for stabilizers and voltage limiters downstream
- Carrying bars included, allowing the transport of the generator by 6/8 persons, at 35/45 kg per person
Transport Dangerous Goods
Generators might be considered as dangerous goods for transport:
- If a shipper or supplier provides written or electronic documentation stating that a flushing and purging procedure for flammable liquid powered engines has been followed in compliance with Special Provision A70 the generator is not subject to IATA DGR regulations
- If not complying with Special Provision A70 then the generator must be managed in compliance to IATA DGR regulations
Instructions for use
Refer to your technical department for power calculations.
For maximum security and grounding/earthing connection, refer to the MSF energy guidelines or the included logbook.
Lifetime: 5000 hours, maintenance every 250 hours.
A specific LogBook / fuel follow-up for this model is included with the generator module as well as an autonomous lighting system for night refuelling.
Precautions for Use
Only supplied in the kit specified below.
Some restricted information has been hidden. Sign in