MULTIMETER clamp, volt.&curr. AC/DC, temp. Hz (F203)

NST PELEMEASMC2

Valid Article



OC subscriptions: included in supply or field order tools (e.g. UniField)
SC subscriptions: included in supply or field tools
OC validations: approved for procurement and use by an OC for international or local orders specifying context and activity in Medical Standard Lists (MSL)

https://unicat.msf.org/web/image/product.template/560731/image_1920?unique=2def352

This combination does not exist.

Add article to list

   

Add Kit To Wishlist

   

MULTIMETER clamp, volt.&curr. AC/DC, temp. Hz (F203)

Form

Professional digital clamp meter from the F200 Series designed for low-voltage maintenance.

Display: Backlit LCD, 6000 counts resolution.

IP protection: IP40 (Protected against solid objects >1mm, no water protection).

Power supply: 1 x 9V Battery (LF22).

Safety standard: 600V CAT IV / 1000V CAT III.

Dimensions (W x H x D): 78 x 222 x 42 mm.

Weight: 340 g (with battery).

Includes:

  • 1 x F203 Clamp Meter

  • 1 x Set of test leads with probes (Red & Black)

  • 1 x 9V Battery

  • 1 x Soft carrying case

  • 1 x Quick start guide (Guide de démarrage)

Per piece

Fit

Electrical Specifications:

  • current AC: range 0.25 A to 600 A (True RMS).

  • current DC: range 0.25 A to 900 A.

  • voltage AC/DC: range 0.15 V to 1000 V.

  • resistance: 0.15 Ohm to 59.99 kOhm.

  • frequency: current (5 Hz – 3 kHz) / Voltage (5 Hz – 20 kHz).

  • temperature: no (Feature available only on F205).

Measurement Performance:

  • True RMS: yes, ensures accuracy on non-linear AC signals.

  • True InRush: captures motor start-up overcurrents.

  • auto-detection: automatically detects AC or DC signal.

  • relative Mode (AREL): yes, allows differential measurement against a reference value.

  • adapter Function: allows connecting external sensors (e.g., luxmeter) with voltage output to be read on the display.

Function

Electrical test tool used for maintenance of tertiary or industrial electrical installations, diagnosing faults, and dimensioning power lines without breaking the circuit.

Primary Functions:

  • load Monitoring: measuring currents up to 600A AC / 900A DC in distribution boards.

  • motor Analysis: using True InRush to verify conductor sizing and breaker settings against actual motor startup surges.

  • troubleshooting: checking continuity, voltage, and resistance in circuits.

Specific applications:

  • solar/DC systems: the 900A DC capability is essential for checking large solar battery banks and inverter inputs/outputs.

  • generator checks: verifying voltage and frequency stability on field generators.

Limitations:

  • no Temperature: unlike the F205, this model cannot measure temperature for HVAC/Cold chain checks.

  • environment: IP40 rating means it is not suitable for wet conditions or heavy dust without extra protection.