(syr. pump Agilia SP) MAINTENANCE TOOLS Z178957

STD EIMTSYPE401

Valid Article

Former Code(s): EEMDSYPS410
CE marking: declaration that the product meets EU standards for health, safety, and environmental protection. The CE marking indicates that the product may be sold freely in any part of the European Economic Area, regardless of its country of origin.
OC subscriptions: included in supply or field order tools (e.g. UniField)
SC subscriptions: included in supply or field tools
OC validations: approved for procurement and use by an OC for international or local orders specifying context and activity in Medical Standard Lists (MSL)

This combination does not exist.

See Related

Add article to list

   

Add Kit To Wishlist

   

(syringe pump Agilia SP) MAINTENANCE TOOLS

Description

Complete title

Author


Publisher


Edition Year


Edition Nr


ISBN number/WHO number (whichever is populated)


Languages None
Online access

Definition

This kit used to perform the preventive maintenance and the calibration of the syringe pump Agilia SP range.

Specifications

Some restricted information has been hidden. Sign in to see this information
Image

Technical specifications

Maintenance kit

  • To calibrate the syringe barrel clasp
    • ​C1 diameter calibration gauge (1)
    • ​C2 diameter calibration gauge (2)
    • ​C3 diameter calibration gauge (3)
  • To calibrate the plunger displacement
    • 20 mm displacement calibration gauge (4)
    • 115 mm displacement calibration gauge (5)
  • To calibrate and control the force sensor
    • Dynamometer with arm spacer for calibration (6)
  • To control the syringe barrel clasp
    • V1 diameter verification gauge (7)
    • V2 diameter verification gauge (8)
    • V4 diameter verification gauge (9)
  • To control the plunger displacement
    • 65 mm displacement verification gauge (10)
  • Screwdrivers
    • Torx T10 screwdriver (11)
    • Torx T8 screwdriver (12)

Agilia USB cable

To be Ordered Separately

  • Agilia Partner Software
  • USB cable Z073491 EEMDINPS406

Instructions for use

Kit for performing preventive maintenance and calibration of the Agilia SP range syringe pump

Precautions for Use

It is necessary to have training to use this kit...

Maintenance

As per Manufacturer recommendation the maintenance kit has to be checked by an accredited body :

  • Every 12 months for all gauges and every 6 months for dynamometer or
  • If the tool fell or could be damaged

MSF requirements

Maintenance kit compatible with the Agilia SP