This system monitoring allows you to always have perfect control over your system from wherever you are and to maximise it's performance. Access your system via our Victron Remote Management (VRM) portal, or access it directly, using the optional GX Touch screen, a Multi-Functional Display (MFD) or our VictronConnect app thanks to its Bluetooth capability.

Specifications:

  • Supply voltage 8 – 70 VDC
  • Power draw without GX Touch 2.8 W @ 12 V
  • Power draw with GX Touch Backlight off: 3.8 W @ 12 V
  • Backlight at max: 4.8 W @ 12 V
  • Mounting Wall or DIN rail, with the DIN 35 Small adapter from Victron
  • VE.Direct - ports 3
  • VE.Bus - 2 paralleled RJ45 sockets
  • VE.Can - Yes
  • BMS-Can port - Yes
  • Bluetooth - Yes
  • Ethernet:10/100 RJ45 socket - isolated except shield
  • USB: 2 USB Host ports and 1 power only port
  • Outer dimensions (h x w x d) 78 x 154 x 48 mm
  • Operating temperature range -20 to +50 °C
  • IP Rating - IP20

Per piece.

Image

Fit

The Cerbo GX is easily mountable and can also be mounted on a DIN Rail using the DIN35 adapter small, (not included). It's separate touchscreen can be bolted on a dashboard, eliminating the need to create perfect cut-outs. Connection is via just one cable. The Bluetooth feature enables a quick connection and configuration via our VictronConnect app.

Function

This system monitor can be used to:

  • Monitor the battery state of charge
  • Power consumption, power harvest from PV, generator, and mains
  • Check tank levels and temperature measurements
  • Control the generator or city grid power input current limit, (auto)start/stop generator(s) or change any setting to optimise the system
  • Follow up on alerts, perform diagnostic checks and resolve complications remotely