ANTI-POLLUTION CHECK VALVE, brass, Ø2"½, MxF threaded

NST CWATCBVANT2HY

Valid Article

SC subscriptions: included in supply or field tools
OC subscriptions: included in supply or field order tools (e.g. UniField)
OC validations: approved for procurement and use by an OC for international or local orders specifying context and activity in Medical Standard Lists (MSL)
https://www.unicat.msf.org/web/image/product.template/579939/image_1920?unique=80eb929

This combination does not exist.

Add article to list

   

Add Kit To Wishlist

   

ANTI-POLLUTION CHECK VALVE, brass, Ø2"½, MxF threaded

Form

Anti-pollution brass check valve ​with two purge buttons in the centre. Threaded 2"1/2 female on one end and male on the other. Per piece.

Fit

To be connected to 2"1/2 female couplings on one end and male on the other.

To ensure a leakage-free assembly on the male thread the use of threading fibres or teflon tape is required.

Function

  • The anti-pollution check valve is interposed between a network and the source supplying this network. It is designed to only allow water to flow in one direction.
  • The anti-pollution check valve differs from a simple non-return valve in that it must be approved "anti-pollution" by the health authorities. A difference must therefore be made to comply with regulatory standards.
  • The arrow on the side indicates the direction that the valve allows liquids to flow towards.
  • Purge buttons for checking valve tightness.
Image