SPACE HEATER

Definition

Forced-air heating device, intended for large spaces, such as stores, community rooms, tents.

Specifications

  • Diesel burner
  • Electric fan
  • Heating capacity (1 kW = 860 kcal/h):
    • CCLIHEATS3- = 31820 kcal/h = 37 kW
    • CCLIHEATS5- = 45580 kcal/h = 53 kW
    • CCLIHEATS8- = 722400 kcal/h = 84 kW
  • Diesel consumption:
    • CCLIHEATS3- = 3.35 litre/hr
    • CCLIHEATS5- = 4.84 litre/hr
    • CCLIHEATS8- = 7.72 litre/hr
  • Tank capacity:
    • CCLIHEATS3- = 51 litre
    • CCLIHEATS5- = 51 litre
    • CCLIHEATS8- = 100 litre
  • Airflow:
    • CCLIHEATS3- = 2000 m3/hr
    • CCLIHEATS5- = 2500 m3/hr
    • CCLIHEATS8- = 4500 m3/hr
  • Power requirement:
    • CCLIHEATS3- = 460 W
    • CCLIHEATS5- = 460 W
    • CCLIHEATS8- = 800 W
  • Options:
    • outlet cone
    • hot air duct
    • Y connection for 2 ducts
    • weatherproofing
    • fuel preheater
    • flue
    • thermostatic regulator

Calculation of the required output

For a quick calculation of the required output of a space heater, use the following formula:

P = ΔT x V x K / 8600

P

power of the space heater, in kW

(1 kW = 860 kcal/h)

ΔT

difference between external temperature and desired internal temperature,

in ºC

Vvolume of the space, in m3
K*coefficient of thermal conductivity

*Nature of insulating material

K

Well insulated brick or breezeblock walls

Glass fibre or polystyrene

Insulated roof or false ceiling

1,2

Uninsulated brick or breezeblock walls

Insulated roof or false ceiling

Moderately insulated room

2,4

Uninsulated brick or breezeblock walls

Uninsulated roof

Badly insulated room

3,5

Wooden or sheet metal walls

Sheet metal or fibre cement roof

Uninsulated room

4

Tent

27

Instructions for use

There are two options:

  • either the heater is placed outside the space and warms cold outdoor air, then blows it inside through a duct
    • => less efficient
    • => air is changed
  • or the heater is placed inside the space and directly warms the indoor air, while a pipe takes the exhaust gases outside
    • => more efficient
    • => air is not changed.

Always ensure that the room is well ventilated, or else remove the exhaust gases.

The fuel used should be of the same quality as that used for vehicles.

Good heat insulation is the first solution to heating problems.