BURNER, GAS, 8000 W, butane, dismountable tripod + HOSE 1.5m
STD
ESTEBURNGA1
Valid Article
Account code:
60210
HS Code:
841620
Last Updated on:
22/11/2024, 22:20:39
Former
Code(s):
-X
The product is part of at least one Kit.
A kit is a collection of products (medical and/or logistic) that are needed for a certain intervention in emergency. The choice and quantity of the articles reflects the MSF protocols for this specific situation. The use of Kits allows to start an intervention without a detailed evaluation.
BURNER, GAS
Definition
Portable gas operating burner, used for heating water in steam autoclaves intended for sterilization.
Specifications
- Burner:
- body, pods and head made of cast iron, black painted
- tap and crown made of brass
- screws and bolts made of stainless steel
- Pods:
- 2 dismountable pods
- positioning at 120º (moulded locations)
- tightening by bolts (screws + nuts)
- Nozzle Ø 1.40 mm for butane and propane
- Pressure reducer for butane and butane/propane mixture, with safety button in case of leak between the pressure reducer and the burner, or disconnection of the bottle
- Rubber pipe, 1.5 m, for butane/propane gas, with expiry date
Technical specifications
- Power: 8000 W
- Consumption: ± 14 kg/24h
- Functions indifferently with butane, propane or butane/propane mixture, provided to be fitted with an adequate pressure reducer:
- pressure of 28/30 mbar for butane and butane/propane mixture
- pressure of 37 mbar for propane
Packaging & Labelling
Unit packaging: cardboard box including:
- 1 burner with instructions for use
- 1 pressure reducing valve with instructions for use
- 1 pipe for butane/propane gas
Instructions for use
Suitable for all the pressure cookers type autoclaves and for the 90 litres autoclave.
Preparation
- Check the device is complete.
- Check the gas pipe is in good condition and not expired.
- Place the pods between the locations foreseen on the burner (120º angles between the 3 pods) and tighten the bolts.
- Push thoroughly the gas pipe on the tap nozzle, and fasten it with a collar.
- Insert the tap (closed) into the location foreseen on the burner's body.
- Push thoroughly the gas pipe on the pressure reducer nozzle, and fasten it with a collar.
- Fasten the pressure reducer on the gas bottle.
- Check the burner tap is closed.
- Open the gas bottle.
- Push the pressure reducer reset button for 3 to 5 seconds.
- Check the absence of leakage by passing a soapy water-soaked sponge over the installation: no bubble = no leak. (Never with a flame, otherwise BANG !)
Some restricted information has been hidden. Sign in
to see this information
Precautions for Use
- The use of gas burner can cause severe accidents: fires, burns, explosions. Provide a fire extinguisher or a sand bucket near by.
- Always fasten securely gas bottles before transporting them to prevent any risk of explosion.
- Before installing a pressure reducer, check that it is adapted to the gas used: 28/30 mbar for butane (the least volatile), 37 mbar for propane (the most volatile, but frost-proof), and 30 mbar for butane/propane mixture (the most widespread outside Europe).
- Before opening the tap of the gas bottle, always check that the tap of the burner is closed.
- Before removing the pressure reducer to replace the bottle, check its tap is completely turned off.
Maintenance
- Regularly clean the burner with soapy water (make sure it is well dry before lighting it).
- Regularly check the state of the gas pipe and replace it either when its expiry date is reached or in case of the slightest doubt.
- Regularly check the absence of leaks as well as the tightening of the various elements.
MSF requirements
Suitable for all the autoclaves, including the 90 litres one which requires a 8000 W power to quickly reach 121º and limit the sterilization cycle time.
Alternative to the modified kerosene burner.