MODULE, RESIDUAL SPRAYING OF INSECTICIDE

STD KWATMSPR10-

Valid Article

Former Code(s): KWATKSPR10-
OC subscriptions: included in supply or field order tools (e.g. UniField)
SC subscriptions: included in supply or field tools
OC validations: approved for procurement and use by an OC for international or local orders specifying context and activity in Medical Standard Lists (MSL)

This combination does not exist.

Add article to list

   

Add Kit To Wishlist

   

MODULE, RESIDUAL SPRAYING OF INSECTICIDE

Definition

Equipment for insecticide residual spraying (IRS). Supplied with personal protective equipment.

Specifications

Including a metallic compression sprayer specific for Insecticide Residual Spraying (IRS). Engineered and designed for vector control based on WHO Pesticide Evaluation Scheme (WHOPES) guidelines.

  • Tank capacity: 10 litres.
  • Closed article: Semco MR10. (Former standard "Hudson X-pert" possibly existing in stocks).

Components

  • PCOOMEAS1G- - MEASURING JUG, 1l, graduated, transparent
  • CWATSPRAHX- - INSECTICIDE SPRAYER (Hudson X-pert) 10l
  • CWATSPRA00S - SIEVE, for spraying
  • L018VECX05E-P - Manual for indoor residual spraying :.. for vector control
  • PHYPTOOTBR- - TOOTHBRUSH, regular
  • PSAFHELMCDO - CAP dust protection, cotton
  • PSAFGLOVCO- - GLOVES chemical resistant, EPI cat. 3, long sleeves, pair
  • PSAFSHIEPFO - PROTECTIVE FACE SHIELD, one size
  • PSAFMASKRF3 - RESPIRATOR FFP3, disposable
  • PSAFOVERLO- - OVERALL, light cotton, one size

Instructions for use

Used only to spray insecticides for vector control. This sprayer must never be used to spray chlorine.

Vector control is part of the minimum WHS requirements in MSF structures. The operator must be trained and follow specific procedures for the operation and maintenance of the equipment. See the operator's manual for precise operation and maintenance instructions and the kit catalogue for more information.

When filling the sprayer with an insecticide, always follow the instructions on the insecticide's label and observe relevant safety rules. Never mix different types of insecticides in the sprayer. Always clean sprayer after use and store clean unit depressurized with open lid.

  • Wear appropriate protective equipment.
  • Do not eat, drink or smoke when using the equipment
  • Do not use this spraying unit for spraying chlorine solutions!

For more information and instructions see "Public Health Engineering in Precarious Situations", MSF, 2nd edition, 2010, chapter 7: vector control.

If in doubt, do ask your technical reference for support and advice

Precautions for Use

Always release pressure:

  • Before removing pump
  • Before removing extension tube, nozzle cap or other part 3.
  • Before trying to unclog nozzle or discharge line
  • Before servicing sprayer in any way
  • When sprayer is left in sun or other warm place

Storage

  • Make sure the unit is always cleaned before storage.
  • Never store an pressurized unit.
  • Follow the storage instructions from manufacturer closely.