MODULE, RESIDUAL SPRAYING OF INSECTICIDE
Valid Article
MODULE, RESIDUAL SPRAYING OF INSECTICIDE
Definition
Equipment for insecticide residual spraying (IRS). Supplied with personal protective equipment.
Specifications
Including a metallic compression sprayer specific for Insecticide Residual Spraying (IRS). Engineered and designed for vector control based on WHO Pesticide Evaluation Scheme (WHOPES) guidelines.
- Tank capacity: 10 litres.
- Closed article: Semco MR10. (Former standard "Hudson X-pert" possibly existing in stocks).
Components
- PCOOMEAS1G- - MEASURING JUG, 1l, graduated, transparent
- CWATSPRAHX- - INSECTICIDE SPRAYER (Hudson X-pert) 10l
- CWATSPRA00S - SIEVE, for spraying
- L018VECX05E-P - Manual for indoor residual spraying :.. for vector control
- PHYPTOOTBR- - TOOTHBRUSH, regular
- PSAFHELMCDO - CAP dust protection, cotton
- PSAFGLOVCO- - GLOVES chemical resistant, EPI cat. 3, long sleeves, pair
- PSAFSHIEPFO - PROTECTIVE FACE SHIELD, one size
- PSAFMASKRF3 - RESPIRATOR FFP3, disposable
- PSAFOVERLO- - OVERALL, light cotton, one size
Instructions for use
Used only to spray insecticides for vector control. This sprayer must never be used to spray chlorine.
Vector control is part of the minimum WHS requirements in MSF structures. The operator must be trained and follow specific procedures for the operation and maintenance of the equipment. See the operator's manual for precise operation and maintenance instructions and the kit catalogue for more information.
When filling the sprayer with an insecticide, always follow the instructions on the insecticide's label and observe relevant safety rules. Never mix different types of insecticides in the sprayer. Always clean sprayer after use and store clean unit depressurized with open lid.
- Wear appropriate protective equipment.
- Do not eat, drink or smoke when using the equipment
- Do not use this spraying unit for spraying chlorine solutions!
For more information and instructions see "Public Health Engineering in Precarious Situations", MSF, 2nd edition, 2010, chapter 7: vector control.
If in doubt, do ask your technical reference for support and advice
Precautions for Use
Always release pressure:
- Before removing pump
- Before removing extension tube, nozzle cap or other part 3.
- Before trying to unclog nozzle or discharge line
- Before servicing sprayer in any way
- When sprayer is left in sun or other warm place
Storage
- Make sure the unit is always cleaned before storage.
- Never store an pressurized unit.
- Follow the storage instructions from manufacturer closely.