LANDCRUISER 4x4 (HZJ78) diesel RHD, for sanitary transport

STD TTOYLC78DSAR

Valid Article

Hazardous materials and products (identified by their 4-digit transport UN-number) must be transported under certain conditions as specified in the MSDS sheet (Material Safety Data Sheet).
OC subscriptions: included in supply or field order tools (e.g. UniField)
SC subscriptions: included in supply or field tools
OC validations: approved for procurement and use by an OC for international or local orders specifying context and activity in Medical Standard Lists (MSL)

This combination does not exist.

Add article to list

   

Add Kit To Wishlist

   

LANDCRUISER 4x4 (HZJ78) sanitary transp.

Definition

Converted vehicle for the sanitary transport of a person or patient, based on an MSF standard vehicle type HZJ78.

The essential part of the conversion consists of the integration of a cell giving space to a functional arrangement and the separation of the steering cabine. The concept and composition of it all allows for a proper cleaning and desinfection of the cell.

The cell or patient unit is exclusively intended for the transport of people.

Capacity of the patient cell:

  • Transport of 1 patient lying on a stretcher (kit transport patient) + 4 places for seated persons, or
  • 8 persons seated (4 double benches)

Capacity in the steering cabin:

  • seats for the driver + 2 places

Different levels of medical equipment are defined to allow the stabilisation of the patient, if needed.

Following the example of a standard vehicle, the converted vehicle incorporates the standard preparation of a vehicle by your technical department, such as the roof, spare wheel(s), hi-lift jack, etc.

Description

The cell or unit in the back is composed of: a floor, lateral panels, a dividing wall with a sliding window separating the cell from the drivers cabin, as well as ceiling coverage made of materials that are cleanable and do not rot.

Technical specifications

By default the unit is equiped with the following equipment:

  • Three perfusion systems on the ceiling with sliding hooks.
  • A needle container, a box for gloves and a waste bin of 3 liters.
  • A holding net fixed on the ceiling.
  • A semi-transparant layer up till 2/3th of the height on the windows.

Materials:

  • partitions made of materials that can be cleaned and do not rot.

Accessories and equipment:

  • The equipment such as the jack, wheel brace, driver toolkit and the telecommunication equipment are all located in the drivers cabin.

Electricity - equipment and installation

  • Four (4) led lights on the ceiling.
  • One (1) ventilation fan with reversible roof operated from the drivers cabin.
  • One (1) fixed revolving light operated from the drivers cabin.
  • Two (2) 12 volt sockets, sigarette lighter style with standard build-in female sockets.
  • Additional battery of 12 volt - 55AH OPTIMA installed parallel for the power supply of the equipment in the medical compartment.
  • Starter battery replaced by a 55AH OPTIMA battery.
  • Relay with voltage threshold to avoid a complete discharge of the starter battery.

Optional equipment and installations

  • simple electronical siren
  • electronical siren for public
  • label "Ambulance" (colour to be specified)
  • Logo "Ambulance" (type, shape and colour to be specified)
Some restricted information has been hidden. Sign in to see this information
Image