CHARGER-INVERTER (Victron-Multiplus C) 12V/70A/1600W+cabling

Definition

The MultiPlus, as the name suggests, is a combined inverter and charger in one package. Its features include a true sine wave inverter, adaptive charging, hybrid PowerAssist technology, plus multiple system integration features.

Specifications

PowerControl: Yes

PowerAssist: Yes

Transfer switch (A): 16

INVERTER

Input voltage range (V DC) 9,5 – 17 V

Output Output voltage: 230 VAC ± 2% Frequency: 50 Hz ± 0,1% (1)

Cont. output power at 25°C (VA): (3) 1600

Cont. output power at 25°C (W): 1300

Cont. output power at 40°C (W): 1200

Cont. output power at 65°C (W): 800

Peak power (W): 3000

Maximum efficiency (%): 93 / 94

Zero load power (W): 8 / 10

Zero load power in AES mode (W): 5 / 8

Zero load power in Search mode (W): 2 / 3

CHARGER

AC Input Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz Power factor: 1

Charge voltage 'absorption' (V DC) : 14,4

Charge voltage 'float' (V DC) : 13,8

Storage mode (V DC) : 13,2

Charge current house battery (A)(4): 70 / 40

Charge current starter battery (A): 4 (12 V and 24 V models only)

Battery temperature sensor: yes

GENERAL

Auxiliary output (5): n. a.

Programmable relay (6) Yes

Protection (2): a - g

VE.Bus communication port: For parallel and three phase operation, remote monitoring and system integration

General purpose com. Port: n. a.

Remote on-off: Yes

Common Characteristics Operating temp. range: -40 to +65°C (fan assisted cooling) Humidity (non-condensing): max 95%

ENCLOSURE

Common Characteristics Material & Colour: aluminium (blue RAL 5012) Protection category: IP 21

Battery-connection battery cables of 1.5 meter

230 V AC-connection: G-ST18i connector Spring-clamp

STANDARDS

Safety EN-IEC 60335-1, EN-IEC 60335-2-29, IEC 62109-1

Emission, Immunity EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3

Notes:

1) Can be adjusted to 60 HZ; 120 V 60 Hz on request

2) Protection key:

a) output short circuit

b) overload

c) battery voltage too high

d) battery voltage too low

e) temperature too high

f) 230 VAC on inverter output

g) input voltage ripple too high

3) Non-linear load, crest factor 3:1

4) At 25˚C ambient

5) Switches off when no external AC source available

6) Programmable relay that can a.o. be set for general alarm,

DC under voltage or genset start/stop function

AC rating: 230 V/4A

DC rating: 4 A up to 35 VDC, 1 A up to 60 VDC

Dimensions

Weight (kg): 10

Dimensions (hxwxd in mm): 375x214x110