UPS dbl conv (DeltaAmplon RT-6K EXT) 6kVA,230VAC+case,no bat

NST PELEUPSD06DXU

Valid Article

OC subscriptions: included in supply or field order tools (e.g. UniField)
SC subscriptions: included in supply or field tools
OC validations: approved for procurement and use by an OC for international or local orders specifying context and activity in Medical Standard Lists (MSL)

This combination does not exist.

See Related

Add article to list

   

Add Kit To Wishlist

   

UPS dbl conv (DeltaAmplon RT-6K EXT) 6kVA,230VAC+case,no bat

Definition

This item is the power supply ONLY

A double conversion uninterruptible power supply (UPS) guarantees a perfect AC supply and is especially suitable for vulnerable and/or expensive equipment such as medical and laboratory equipment.

There is no connection between the incoming power and the outgoing power; all possible electrical problems such as voltage spikes are eliminated.

To function in the case of a power-cut it needs a battery pack, which has to be ordered separately.

Specifications

  • Input voltage range 100 - 300 V (note that between 100 V and 180 V input voltage, the output power is reduced by 50 - 100%; full power is available only at 180V AC and above). At higher (>300 V) or lower (<100 V) voltages the UPS switches to battery power
  • Input and output frequency 50 or 60 Hz
  • Power factor >0.99
  • Efficiency (full load) >92%
  • Without battery

Includes:

  • GES201B109035-N New RT 5-20kVA 3U empty EBC 20x9Ah - no battery
  • 3246796000-S35 Air filter 2U for RT series 5-10kVA - left (10 pcs in package)
  • 3247040400-S35 Air filter 2U for RT series 5-10kVA - right (10 pcs in package)
  • 3246824700-S35 Air filter 2U for RT series 5-10kVA - fixing strips (40 pcs in package) (1 UPS will need 2 filter+4 strips)
Some restricted information has been hidden. Sign in to see this information

Instructions for use

This UPS is primarily intended to protect the equipment connected to it. It also provides back-up power but it cannot be configured to allow a long back-up time. An additional battery pack can be added to give a longer back-up time but the charger is integral and cannot be changed.

The high output power makes it suitable for almost any laboratory or medical facility. The UPS is delivered without a power cord and needs to be wired with an appropriate cable. Only connect 30 mA residual current devices (RCD) on the output of the UPS. RCD installed on input may experience nuisance tripping. For more details and advice: contact your logistics department.

MSF requirements

The chosen model enables input voltages of 100 – 300 V to be converted to 230 V; the input is compatible with 50 or 60 Hz; the output can be programmed to the local frequency if need be.