GENERATOR (FG Wilson P165-5) 150kVA 400V 50Hz 3ph, diesel
Discontinued Article
GENERATOR (FG Wilson P165-5) 165kVA 400V 50Hz, diesel, sil.
Definition
The FG Wilson P165-5 is powered by the Perkins 1106A-70TAG2, 6 cylinder turbo charged water cooled 1500 rpm diesel engine, 50 Hz, alternator FGL30100, AVR, all housed in a quiet, durable and weather resistant acoustic enclosure.
Controlled by a control panel FG100 with a start/stop button and a single menu layout for ease of navigation, but can also come with an alternative control panel type like for example DeepSea.
A standard version comes with a bunded long range fuel tank, a water heater and a battery charger, but different versions can be specified when ordering.
Specifications
- output ratings: prime/standby: 150/165 kVA at 400/230V, 50 Hz
- engine: Perkins 1106A-70TAG2
- alternator: FG Wilson FGL30100 or equivalent
- control panel: FG100 or alternative
- fuel tank capacity: 327 litres
- fuel consumption at 100% load: prime/standby: 32.4/35.1 litres
- noise level: 68dB(A) at 7 m
- running time: 13.1 hours at 75% load
- hard wired output only, no socket
Technical specifications
Engine:
- 6 cylinder, 4 stroke, in line diesel engine
- speed: 1500 rpm (for 50 Hz)
- gross engine power: prime/standby: 136/149 kW
- turbocharged, water cooled with mechanical governor
- lubrication: engine oil, 16.5 liters, CH4/CI415W-40
Alternator:
- output: 400/230 V, 50 Hz, 3-Phase
- power rating: prime/standby: 150/165 kVA, 120/132 kW
- excitation system: SHUNT
- AVR Model: R120 for standard alternator (if other alternator is chosen the AVR must match that type)
Dimensions
LxWxH: 2450 x 1010 x 1544 mm
Weight: 1434 kg
Transport Dangerous Goods
Generators might be considered as dangerous goods for transport:
- If a shipper or supplier provides written or electronic documentation stating that a flushing and purging procedure for flammable liquid powered engines has been followed in compliance with Special Provision A70 the generator is not subject to IATA DGR regulations
- If not complying with Special Provision A70 then the generator must be managed in compliance to IATA DGR regulations
Instructions for use
For power calculations refer to your technical department .
Do not fill the fuel tank while the engine is running.
For maximum safety and earthing, refer to the MSF guidelines on energy.
Maintenance
Usual maintenance interval is every 250 hours for this type of generator. For certain countries/locations a different maintenance interval might be applicable, check this with your technical department.
Use the logbook generator 1500 rpm , article code: L041MECM19E-P.