VOLTAGE LIMITER (Voltshield A/C guard) 230V, 20A, 1 phase

Form

Over & Under Voltage Protection. Specifications:

  • max power: 20 ampere
  • wait time: 4 minutes time delay
  • Overvoltage disconnect: can be set between 230 - 300 V
  • Undervoltage disconnect: can be set between 150 - 230 V

Closed article: Solltek Voltshield A/C Guard, with manufacturer reference 92622020. Per piece.

Image

Fit

Attached on a wall and connected directly to the power input of an air conditioner, fridge, freezer or such.

Function

The A/C Guard's Automatic Voltage Switcher functions protect against Low voltage, high voltage, power-back surges, power fluctuations and surges/ spikes. It features a start up delay of about 4 minutes to prevent frequent switching on and off during fluctuations. The A/C Guard has a built-in microprocessor which adds the advanced feature TimeSave™ to save on down time. TimeSave™ means that when the mains returns to normal after any event, the A/C Guard checks the duration of the OFF time. If the unit has been off for more than 4 minutes then it will switch the air-conditioner on within 10 seconds rather than the standard 4 minutes. If however, the unit has been off for less than 4 minutes, the A/C Guard will ensure that it will remain off up to 4 minutes and then restarts automatically. An integral circuit breaker enhances the protection offered by the A/C Guard. If a short circuit or over-load occurs, the circuit breaker detects the fault and the air conditioner is safely disconnected. To resume operation, simply switch the A/C Guard circuit breaker on again, assuming the cause of the overload has been removed. The air conditioner restart automatically after an intelligent time delay.

Ideal for:

  • Air conditioners
  • Large fridge/freezer