VOLTAGE LIMITER (Voltshield A/C guard) 230V, 16A, 1 phase

STD PELEVOLL216G

Valid Article

The product is part of at least one Kit. A kit is a collection of products (medical and/or logistic) that are needed for a certain intervention in emergency. The choice and quantity of the articles reflects the MSF protocols for this specific situation. The use of Kits allows to start an intervention without a detailed evaluation.
OC subscriptions: included in supply or field order tools (e.g. UniField)
SC subscriptions: included in supply or field tools
OC validations: approved for procurement and use by an OC for international or local orders specifying context and activity in Medical Standard Lists (MSL)

This combination does not exist.

See Related

Add article to list

   

Add Kit To Wishlist

   

VOLTAGE LIMITER (Voltshield A/C guard) 230V, 16A, 1 phase

Form

Over & Under Voltage Protection. Specifications:

  • max power: 16 ampere
  • wait time: 4 minutes time delay
  • Overvoltage disconnect: can be set between 230 - 300 V
  • Undervoltage disconnect: can be set between 150 - 230 V

Closed article: Solltek Voltshield A/C Guard, with manufacturer reference 92621620. Per piece.

Image

Fit

Attached on a wall and connected directly to the power input of an air conditioner, fridge, freezer or such.

Function

The A/C Guard's Automatic Voltage Switcher functions protect against Low voltage, high voltage, power-back surges, power fluctuations and surges/ spikes. It features a start up delay of about 4 minutes to prevent frequent switching on and off during fluctuations. The A/C Guard has a built-in microprocessor which adds the advanced feature TimeSave™ to save on down time. TimeSave™ means that when the mains returns to normal after any event, the A/C Guard checks the duration of the OFF time. If the unit has been off for more than 4 minutes then it will switch the air-conditioner on within 10 seconds rather than the standard 4 minutes. If however, the unit has been off for less than 4 minutes, the A/C Guard will ensure that it will remain off up to 4 minutes and then restarts automatically. An integral circuit breaker enhances the protection offered by the A/C Guard. If a short circuit or over-load occurs, the circuit breaker detects the fault and the air conditioner is safely disconnected. To resume operation, simply switch the A/C Guard circuit breaker on again, assuming the cause of the overload has been removed. The air conditioner restart automatically after an intelligent time delay.

Ideal for:

  • Air conditioners
  • Large fridge/freezer