CLINICAL CHEMISTRY ANALYZER (Erba XL200), w/o ISE module
STD
ELAECCHE7B-
Valid Article
HS Code:
{}
Last Updated on:
12/04/2024, 17:42:39
W0201010105 - Chemistry analysers - low routine (with ise mode test/h <= 400)
European Medical Device Nomenclature (EMDN) is the nomenclature of use by manufacturers when registering their medical devices in the EUDAMED database. EMDN is characterised by its alphanumeric structure that is established in a seven-level hierarchical tree.
Hazardous materials and products (identified by their 4-digit transport UN-number) must be transported under certain conditions as specified in the MSDS sheet (Material Safety Data Sheet).
Thermosensitive codes are defined for storage and transportation temperature requirements of the products.
CHEMISTRY ANALYZER (Erba XL200), w/ISE module
Please contact your laboratory and biomedical advisor when considering the purchase of a clinical biochemistry automate.
Definition
Benchtop clinical chemistry automate with optional ISE module, measuring clinical chemistry parameters and ion-selective quantification of specific electrolytes (Na+, K+, Cl-, Li+) in serum,plasma, urine and cerebrospinal fluid (CSF).
Specifications
ISE: ion-selective electrodes
Some restricted information has been hidden. Sign in
to see this information
Components
- ISE module (optional)
- Touch screen
- Arm
Technical specifications
- For laboratories running 30-70 samples a day
- Throughput:
- 200 photmetric tests/hour
- 400 ISE tests/hour
- ISE simultaneous measurement: max. 45 photometric tests + 4 ISE
- Sample: serum, plasma, urine, CSF
- Analyzer compatible with vacuum tubes - centrifugation outside the device
- Reagent Tray: 50 refrigerated positions (8-12°C) 5, 20, 50 ml reagent containers
- Sample Tray (39 positions):
- Outer ring – 30 position for samples
- Inner ring – 9 positions for blanks, standards, calibrators
- Reagent Dispensing: One dispensing probe with liquid-level sensor with dispensed volumes: R1 50-300 μl – adjustable in 1 μl step R2 10-200 μl – adjustable in 1 μl step
- Min. reagent volume: 180 μl
- Reaction Tray: 45 reusable hard glass cuvettes, optical path length 5 mm
- PC requirements: Operating system: MS Windows XP or MS Windows 7, Pentium 4, RAM 2 GB, HDD 200 GB
- Power supply: 220 V ± 10 %, 50 Hz ± 5%, 600 VA
- Mixing system: Independant stirrer
- Barcode reader: Built in barcode reader for samples and reagents
- Water consumption: Max. 6 l/hr
Dimensions
- Dimensions: 810 mm x 800 mm x 1160 mm
- Weight: 120 kg
Instructions for use
Precautions for Use
Secure all electrical devices in the laboratory with a UPS double conversion (see related articles below). To define the best sizing of the UPS, contact your biomedical or energy referent.
MSF requirements
Please contact your laboratory and biomedical advisor when considering the purchase of a clinical biochemistry automate.