ULTRASOUND(Sonosite MT) +TRANSD. C5-1, maternity package FR.

STD EDIMULSP17AF

Valid Article


CE marking: declaration that the product meets EU standards for health, safety, and environmental protection. The CE marking indicates that the product may be sold freely in any part of the European Economic Area, regardless of its country of origin.
Z11040104 - Multidisciplinary ultrasound scanners (internal and cardiology, etc.)
European Medical Device Nomenclature (EMDN) is the nomenclature of use by manufacturers when registering their medical devices in the EUDAMED database. EMDN is characterised by its alphanumeric structure that is established in a seven-level hierarchical tree.
In Europe, medical material that fulfills the definition of a medical device according to the MDR (Medical Device Regulation) is classified into 4 classes
The order of this product needs to be justified and is only acceptable under certain conditions.
Hazardous materials and products (identified by their 4-digit transport UN-number) must be transported under certain conditions as specified in the MSDS sheet (Material Safety Data Sheet).

OC subscriptions: included in supply or field order tools (e.g. UniField)
SC subscriptions: included in supply or field tools
OC validations: approved for procurement and use by an OC for international or local orders specifying context and activity in Medical Standard Lists (MSL)

https://unicat.msf.org/web/image/product.template/589356/image_1920?unique=0691ebf

This combination does not exist.

Add article to list

   

Add Kit To Wishlist

   

ULTRASOUND(Sonosite MT) +TRANSD. C5-1, maternity package

Definition

Ultrasound-based diagnostic imaging apparatus used to visualize subcutaneous body structures. High image quality for abdominal, nerve, vascular, cardiac, venous access, pelvic and superficial imaging.

Specifications

Some restricted information has been hidden. Sign in to see this information

Quality standards

EN 60601-2-37, 2008, +A1 2015 Medical electrical equipment - Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment

Components

  • Ultrasound machine P33000
  • Transducers with armored cables
    • C5-1 ref. P23119
Image

Technical specifications

ULTRASOUND SYSTEM​​​

  • Power supply:
    • System operates via battery or AC power
    • Rechargeable lithium-ion battery < 100 Wh.
    • AC: universal power adapter, 100-240 VAC,
    • 50/60 Hz input, 15 VDC output

DIMENSIONS

  • System:
    • Weight: 13.0 lbs (5.6 kg) with battery
    • Length: 12.9 in. (32.7cm)
    • Width: 12.9 in. (32.7cm)
    • Height 12.5 in. (31.8cm with lid raised)
  • Stand
    • Weight: 41.0 lbs (18.6 kg)
    • Depth: 27.3 in. (69.2 cm)
    • Width: 27 in. (69 cm)
    • Height: 48.7 in. (123.7 cm) maximum, 41 in. (104.1 cm) minimum
    • Height range : 6.1 in. (15.5 cm)
    • storage bin capacity: 11 lbs (5kg.)
    • total stand weight with system and peripherals: 96.12 lbs (43.6kg) maximum
  • Display:
    • Width: 11.2 in. (28.5cm)
    • Height 7.5 in. (20cm)
    • Diagonal: 13.5 in. (34.2 cm)
    • Resolution: 1920 x 1280 px

IMAGING MODES

  • 2D (256 gray shades)
  • Color Doppler (256 colors)
  • Colour Power Doppler (CPD) (256 colors)
  • M Mode
  • PW (Pulsed wave Doppler)
  • CW (Continous wave Doppler)

Additionally, the system includes advanced imaging technologies:

  • Tissue Doppler Imaging (TDI)
  • Tissue Harmonic Imaging (THI)​

SHIPPING LIMITS

System (no batteries), transducers, ECG and stand head/platform

  • Temperature between -35°C and +65°C (-31 - 149°F)
  • Relative humidity: 15 - 95 %
  • Atmospheric pressure: 500- 1060 hPa (0.5 - 1.05 ATM)

System batteries and stand with stand battery:

  • -20°C and +60°C (-4 - 140°F)
  • Relative humidity: 15 - 95 %
  • Atmospheric pressure: 500- 1060 hPa (0.5 - 1.05 ATM)

DESIGNED FOR DURABILITY
Sonosite MT undergoes rigorous testing, including repeated 3-foot drops onto hard surfaces to simulate real-world impacts.


EASY TO CLEAN
The durable all-touch interface is designed for easy maintenance and built to withstand repeated cleaning, helping you maintain hygiene in clinical settings.


SPLASH RESISTANT
Sealed edge-to-edge screens protects Sonosite MT from common clinical spills and splashes.

Dimensions

32.7 cm L x 32.7 cm W x 31.8 cm (with lide raised) H

Transport Dangerous Goods

  • UN3481 Lithium ion batteries contained in equipment​
Image

Supplied with the Article

  • MT Ultrasound
  • Transducer with armored cables
    • C5-1: Abdomen, Lung, MSK, Nerve, OB, Early OB, GYN P23119
  • Stand P33001
  • Auxiliary Battery P33003
  • Carry case P33008
  • System Battery P33009
  • COUPLING AGENT, 250 ml bot.
  • Power Supply + power cord EU P33287
  • Power Supply + power cord UK P33287
  • User manual and service guides (several languages)
  • 5-year warranty

To be Ordered Separately

Having the correct transducer(s) available is CRUCIAL for performing Ultrasound examinations.

Additional transducers are most likely required. See Edge 2 Ultrasound Probes (accessories).

Transducer needs vary by project site. To order the most suitable transducers for your site, please contact POCUS@msf.org or the POCUS advisor for your section for further advice.

Consider ordering a backup of the transducer the project uses most frequently.

Recommended additional orders

MSF code

Item

Notes

EEMDPOCS05TEBPOWER CORD, 5m, 10A, 230V, type E+F/EUR, C13 connector,blackRecommend 1 backup depending on plug type
EEMDPOCS05TGBPOWER CORD, 5m, 10A, 230V, type G/UK, C13 connector, blackRecommend 1 backup depending on plug type

EDIMULSC1CA*

Ultrasound Gel, 250 ml bot.)

Consumption: 1 bottle = 10 exams, order min 40/month

SDISSUQA2B**

Detergent/Disinfectant – Surfanios
For surfaces, 2 L tin + dosing pump

Concentrated solution to be
diluted before use, needed for
daily IPC

PELEVOLL207T***

Voltage Protection - VOLTAGE LIMITER with timer, 180-265V, 7A, EUR, for fridge

For voltage stabilization, if needed

*Ultrasound exams are not possible without gel! Please order months in advance, and recommend ordering more than necessary until exact usage/month is well known. This gel has a long shelf-life with no temperature requirements. NEVER use alcohol or oil based products (Sterilium, povidone-iodine, alcohol gel, gel cleansers) as these may damage the transducer. Sterile lubrication or plain WATER may be used as alternatives.

**Diluted solution, made fresh daily, should be used to clean transducers after EVERY patient exam. NEVER use alcohol or oil based products (Sterilium, povidone-iodine, alcohol gel, gel cleansers) as these may damage the transducer.

*** Only necessary if the electrical network is NOT already protected by MSF standard double-conversion UPS

Additional orders depending on the use of the equipment

MSF code

Item

Notes

EDIMULSA1710 (UD Sonosite MT) POWER SUPPLY + POWER CORD EU 1m, P33287Only if the power supply is needed:
2-prong “EU” plug – Recommend 1 backup depending on plug type
EDIMULSA1711 (UD Sonosite MT) POWER SUPPLY + POWER CORD UK 1m, P33287Only if the power supply is needed:
2-prong “EU” plug – Recommend 1 backup depending on plug type

Instructions for use

If gel is not readily available, it can be replaced with water. Never use alcohol, oil or any other fluids as they can damage the transducer.

If a patient shows infectious lesions, the end of the transducer must be covered with a male condom or glove during the examination.

For advanced obstetric applications, a vaginal transducer (ICT x/ 8-5MHz) can be ordered separately (see accessories). This transducer is intended for trained and experienced users. It must always be used with a male condom.

Some restricted information has been hidden. Sign in to see this information

Precautions for Use

It is mandatory to protect the device with a double conversion UPS, and a voltage limiter with timer (see related articles below)

Storage

System (no batteries), transducers, ECG and stand head/platform

  • Temperature between -35°C and +65°C (-31 - 149°F)
  • Relative humidity: 15 - 95 %
  • Atmospheric pressure: 500- 1060 hPa (0.5 - 1.05 ATM)

System and stand batteries:

  • -20°C and +60°C (-4 - 140°F) for 1 month; -20°C and +45°C (-4 - 113°F) for 3 months; -20°C and +23°C (-4 - 73°F) for 1 year
  • Relative humidity: 15 - 95 %
  • Atmospheric pressure: 500- 1060 hPa (0.5 - 1.05 ATM)

MSF requirements

This high-resolution ultrasound system offers such performance features as larger cart-based systems in a hand-carried, stand-alone unit.

Alternative to the MSF standard Sonosite Edge 2.

  • The MT is Sonosite's newer version of the Edge 2. The Edge 2 was introduced in 2016 while the MT was introduced in 2025.
  • The performance and image quality of the MT are superior to the Edge 2 but it has an even sturdier design and features newer technology.
  • The interface and functionality of the MT is very similar to the M-turbo but even easier to use and customizable interfaces can be created for MSF or specific types of sites.
    And in our experience, most MSF users are quite satisfied with the Edge 2. Users who are already accustomed to the Edge 2 will adapt very quickly to the MT.

5-year warranty on ultrasound system and transducers and excellent technical and customer service support from Sonosite

Some restricted information has been hidden. Sign in to see this information
Some restricted information has been hidden. Sign in to see this information