(mb GeneXpert) TEST MTB/RIF-ULTRA, cartr. GXMTB/RIF-ULTRA-50

STD ELAEMBIT111

Valid Article

Single use
A single-use device, also referred to as a disposable device, is intended for use on one patient during a single procedure. It is not intended to be reprocessed (i.e., cleaned and disinfected or sterilized).
CE marking: declaration that the product meets EU standards for health, safety, and environmental protection. The CE marking indicates that the product may be sold freely in any part of the European Economic Area, regardless of its country of origin.
The order of this product needs to be justified and is only acceptable under certain conditions.
Hazardous materials and products (identified by their 4-digit transport UN-number) must be transported under certain conditions as specified in the MSDS sheet (Material Safety Data Sheet).
Thermosensitive codes are defined for storage and transportation temperature requirements of the products.
OC subscriptions: included in supply or field order tools (e.g. UniField)
SC subscriptions: included in supply or field tools
OC validations: approved for procurement and use by an OC for international or local orders specifying context and activity in Medical Standard Lists (MSL)

This combination does not exist.

See Related

Add article to list

   

Add Kit To Wishlist

   

(mb GeneXpert) TEST MTB/RIF-ULTRA, cartridge

CAUTION

This test (= 1 cartridge) is worded and codified by unit to make the order easier, but it is always packaged in kit of 50.

Definition

The Xpert MTB/RIF-Ultra assay runs on the GeneXpert System.

It is a cartridge-based, semiquantitative diagnostic test that can detect Mycobacterium tuberculosis (MTB) complex and resistance to rifampicin (RIF).

The Xpert® MTB/RIF-Ultra assay purifies, concentrates, amplifies (by real-time PCR) and identifies targeted nucleic acid sequences in the genome of M. tuberculosis complex bacteria, and provides results from unprocessed sputum samples in less than 80 minutes, with minimal biohazard and limited technical training required to operate.

Specifications

Some restricted information has been hidden. Sign in to see this information

Technical specifications

The Xpert MTB/RIF-Ultra kit contains sufficient reagent to test 50 specimens

The kit contains:

  • 50 Xpert MTB/RIF-Ultra assay cartridges with integrated reaction tubes:
    • Beads 1 and 2 (freeze-dried) : 2 of each per cartridge
    • Bead 3 (freeze-dried) : 1 of each per cartridge
    • Reagent 1 : 4 ml per cartridge
    • Reagent 2: 4 ml per cartridge
  • 50 Sample reagent bottles: 8 ml per bottle
  • 60 disposable transfer pipettes
  • 1 CD (assay definition, instructions for use)

Packaging & Labelling

1 kit = 50 tests (5 pouches of 10 cartridges)

Transport Dangerous Goods

  • UN2920
  • Hazard Class: 8 (3)
  • Packing group: II
  • Proper Shipping Name: Corrosive liquid, flammable, n.o.s.

Instructions for use

Follow the instructions for use

Please consult the “Updated laboratory procedures, 2022” available online via the Laboratory working Group sharepoint page: Laboratory Procedures and Resources.

https://msfintl.sharepoint.com/sites/msfintlcommunities/LabWG/SitePages/Laboratory-Manual-page.aspx

For offline access, contact your laboratory advisor.

Some restricted information has been hidden. Sign in to see this information

Waste management

Substance with hazardous characteristics. Please contact your watsan referent for advice on proper disposal.

Detailed hazard and precautionary information can be found in the safety data sheet (SDS).

To be noted is the relative large volume of additional waste generated by Xpert MTB/RIF Ultra compared to smear microscopy.

Using the Sample Reagent reduced by 6 log organ viability of a sample.

Classification EC Regulation N° 1272/2008

  • Flammable Liquids 3 - H226
  • Skin Corrosion 1B - H314
Image Image Image

Signal Word

Danger

H226Flammable liquid and vapour.
H314Causes severe skin burns and eye damage.
H341Suspected of causing genetic defects (state route of exposure if it is conclusively proven that no other routes of exposure cause the hazard).
H361Suspected of damaging fertility or the unborn child (route of exposure if it is conclusively proven that no other routes of exposure cause the hazard).
H372Causes damage to organs (or state all organs affected, if known) through prolonged or repeated exposure (state route of exposure if it is conclusively proven that no other routes of exposure cause the hazard).
P210Keep away from heat/sparks/open flames/hot surfaces. – No smoking.
P233Keep container tightly closed.
P260Do not breathe dust/fume/gas/mist/vapours/spray.
P264Wash … thoroughly after handling
P280Wear protective gloves/protective clothing/eye protection/face protection
P310Immediately call a POISON CENTER or doctor/physician.
P321Specific treatment (see ... on this label)
P363Wash contaminated clothing before reuse.
P301 + P330 + P331IF SWALLOWED: rinse mouth. Do NOT induce vomiting
P303 + P361 + P353IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing.
P304 + P340IF INHALED: Remove to fresh air and keep at rest in a position comfortable for breathing.
P305 + P351 + P338IF IN EYES: rinse cautiously with water for several minutes. If the victim wears contact lenses, remove them if possible. Keep rinsing
P370 + P378In case of fire: Use... for extinction.
P501Dispose of contents/container to location in accordance with local and regional/ national/ international regulations
Some restricted information has been hidden. Sign in to see this information
Some restricted information has been hidden. Sign in to see this information